Direkt zum Inhalt

i700

The i700 cabinet servo inverter is suitable for dynamic motion control and multi-axis applications. The interconnected system of single or double axis devices, in combination with the appropriate supplier and our controllers, is the right choice for automation applications.
Our controllers, such as the c520, can be used to conveniently solve almost all control tasks for coordinated movement of multiple axes with high dynamics. Thus, modern and modular machine controls can be implemented based on our software modules.
The i950 cabinet servo inverter can be used as a power extension of the i700 cabinet servo inverter in the range from 22 to 110 kW.

Highlights

  • Integrated DC-bus connection
  • Small overall width from 50 mm for the double axis
  • Axis modules capable of multiple overloads for peak output currents between 5 and 64 A, double axes up to 32 A
  • Autotuning function for quick and easy controller adjustment
  • "Safe Torque Off (STO)" safety function
Bild
    Title File Document type Version
    Flyer i700 cabinet servo inverter EN Flyer v1.1 en
    Fault ID: 0016
    Hex: 0016
    Description: I2xt overload
    Keypad display: OC6
    Cause Remedy Severity/response
    • Frequent and too long acceleration processes with motor overcurrent.
    • Permanent motor overload with Imotor >Irmotor

    Check drive dimensioning.

    Fault ID: x018
    Hex: x018
    Description: I2xt overload advance warning
    Keypad display: OC8
    Cause Remedy Severity/response
    • Frequent and too long acceleration processes with motor overcurrent.
    • Permanent motor overload with Imotor >Irmotor

    Check drive dimensioning.

    Fault ID: 0015
    Hex: 0015
    Description: I x t overload
    Keypad display: OC5
    Cause Remedy Severity/response
    • Frequent and too long acceleration with overcurrent
    • Continuous overload with Imotor > 1.05 x Irx

    Check drive dimensioning.

    Fault ID: 0012
    Hex: 0012
    Description: Motor cable earth fault
    Keypad display: OC2
    Cause Remedy Severity/response

    One of the motor phases has
    earth contact.

    • Search for cause of short circuit.
    • Check motor cable.
    Fault ID: 0011
    Hex: 0011
    Description: Short circuit of motor cable
    Keypad display: OC1
    Cause Remedy Severity/response

    Short circuit

    Excessive capacitive charging
    current in the motor cable.

    • Search for cause of short circuit.
    • Check motor cable.

      Use motor cable which is shorter
      or of lower capacitance.