i550 protec
The award-winning i550 protec frequency inverter uses the same tried-and-tested technology used in our control cabinet inverters. It only differs in terms of a higher degree of housing protection and an adapted design. If there is not enough space in the control cabinet or the inverter has to be mounted close to the motor in various machine modules, then this versatile and reliable device is the right solution. Thanks to the extension box, a disconnect switch and operating elements can be used.
The requirements of the Ecodesign Directive, Standard EN IEC 61800-9-2, are met.
Application areas: Conveyor drives, traveling drives, winding drives, hoist drives, extruders, packaging machines, pumps, fans, ...
Highlights
- Decentralized drive with IO-Link interface V1.1
- Integrated diagnostic interface (micro USB) for service purposes
- Versions with or without repair switch, with keypad or WLAN module for easy commissioning
- Optionally available with "Safe Torque Off (STO)" with SIL 3 (EN IEC 61508) and Performance Level e (EN ISO 13849-1)
Documentation
Error codes
| Cause | Remedy | Severity/response |
|---|---|---|
DC-bus voltage has exceeded the error threshold for overvoltage due to a too high braking energy or a too high mains voltage. The error threshold (display in 0x2540:006 (P208.06) results from the setting of the rated mains voltage in 0x2540:001 (P208.01). |
Reduce dynamic performance of the load profile. Check mains voltage. Check settings for brake energy 0x2541:001 (P706.01) = [0]: Connect brake resistor to the power unit and activate the integrated brake chopper |
Fault |
| Cause | Remedy | Severity/response |
|---|---|---|
Operation on uninterrupted 1x230V current supply (UPS) has been activated: Only a reduced output current is provided. |
Switch back to operation with regular mains voltage |
Warning |
| Cause | Remedy | Severity/response |
|---|---|---|
Mains phase failure |
|
Fault |
| Cause | Remedy | Severity/response |
|---|---|---|
DC bus voltage is lower than specified in C0173. |
|
cawc |
| Cause | Remedy | Severity/response |
|---|---|---|
Braking energy is too high. (DC−bus voltage is higher than set in C0173.) |
|
| Cause | Remedy | Severity/response |
|---|---|---|
|
Check drive dimensioning. |
| Cause | Remedy | Severity/response |
|---|---|---|
|
Check drive dimensioning. |
| Cause | Remedy | Severity/response |
|---|---|---|
|
Check drive dimensioning. |
| Cause | Remedy | Severity/response |
|---|---|---|
One of the motor phases has |
|
| Cause | Remedy | Severity/response |
|---|---|---|
Short circuit Excessive capacitive charging |
|
| Cause | Remedy | Severity/response |
|---|---|---|
Device utilisation (ixt) too high by frequent and too long acceleration processes. |
Check drive sizing.
|
Fault (configurable)
Blocking time: 2 s Setting parameters: 0x2D40:005 (P135.05) |
| Cause | Remedy | Severity/response |
|---|---|---|
Motor thermally overloaded, e. g. by an impermissible continuous current or by frequent or too long acceleration processes. |
Check drive sizing.
|
Fault (configurable)
Blocking time: 2 s Setting parameters: 0x2D4B:003 (P308.03) |
| Cause | Remedy | Severity/response |
|---|---|---|
Short circuit of motor cable |
Check motor cable for short circuit. |
Fault
Blocking time: 2 s |
| Cause | Remedy | Severity/response |
|---|---|---|
|
|
Fault
Blocking time: 2 s |
| Cause | Remedy | Severity/response |
|---|---|---|
|
|
Fault
Blocking time: 2 s |