0x2D4D:003 Manufacturer Lenze Product category i950 Parameter Motorauslastung (i²xt) - spezifische Kennlinie: x2 = n02/nN (n02 = Grenze reduzierte Kühlung) Data type U16 Default setting 0 % Attributes - M - Mapping False
0x2D4D:002 Manufacturer Lenze Product category i950 Parameter Motorauslastung (i²xt) - spezifische Kennlinie: y1 = i01/iN (x1) Data type U16 Default setting 100 % Attributes - M - Mapping False
0x2D4D:001 Manufacturer Lenze Product category i950 Parameter Motorauslastung (i²xt) - spezifische Kennlinie: x1 = n01/nN (n01 ~ 0) Data type U16 Default setting 0 % Attributes - M - Mapping False
0x2D4C:004 Manufacturer Lenze Product category i950 Parameter Thermisches Modell der Motorauslastung (i²xt): Startwert Data type U16 Default setting 0 % Attributes - M - Mapping False
0x2D4C:002 Manufacturer Lenze Product category i950 Parameter Thermisches Modell der Motorauslastung (i²xt): Thermische Zeitkonstante - Blechpaket Data type U16 Default setting 852 s Attributes - M - Mapping False
0x2D4C:001 Manufacturer Lenze Product category i950 Parameter Thermisches Modell der Motorauslastung (i²xt): Motorauslastung (i²xt) Data type U16 Default setting 60 s Attributes - M - Mapping False
0x2D46:001 Manufacturer Lenze Product category i950 i550 Parameter Überstromüberwachung: Schwellenwert Data type U16 Default setting 5.4 A Attributes - M - Mapping False
0x2D45:003 Manufacturer Lenze Product category i950 i550 Parameter Erkennung von Motorphasenausfall: Spannungsschwelle Data type U16 Default setting 10.0 V Attributes - M - Mapping False
0x2D44:001 Manufacturer Lenze Product category i950 i550 Parameter Überdrehzahlüberwachung: Schwellenwert Data type U16 Default setting 8000 rpm Attributes - M - Mapping False
0x2D40:009 Manufacturer Lenze Product category i950 Parameter Geräteauslastung ixt: Fehlerschwelle der Gesamtauslastung Data type U16 Default setting x % (Read only) Attributes - M - Mapping False