8400 HighLine
The 8400 HighLine frequency inverter is suitable for speed control with simple motion control and positioning tasks.
The requirements of the Ecodesign Directive, Standard EN IEC 61800-9-2, are met.
Application areas: rotary indexing tables, storage systems (intralogistics), form-fill-seal machines (packaging industry), ...
Highlights
- Integrated positioning control
- Up to 15 selectable positioning points including the respective travel profile
- Optionally available with "Safe Torque Off (STO)" with SIL 3 (EN IEC 62061/EN IEC 61508) and Performance Level e (EN ISO 13849-1)
Documentation
| Title | Language | Document type | Version | File |
|---|---|---|---|---|
| "Actuator Torque" technology application | DE | Commissioning | 1.1 | |
| "Actuator Torque" technology application | EN | Commissioning | 1.1 | |
| PLC Designer V3 Application Samples | DE | Commissioning | 2.1 | Dokumentum
|
| PLC Designer V3 Application Samples | EN | Commissioning | 2.1 | Dokumentum
|
| CANopen 8400 | DE | Operating instructions | 4.2 | Dokumentum
|
| CANopen 8400 | EN | Operating instructions | 4.2 | Dokumentum
|
| EtherCAT® 8400 E84AYCET | DE | Operating instructions | 3.1 | Dokumentum
|
| EtherCAT® 8400 E84AYCET | EN | Operating instructions | 3.1 | Dokumentum
|
| EtherNet/IP™ 8400 E84AYCEO | DE | Operating instructions | 3.0 | Dokumentum
|
| EtherNet/IP™ 8400 E84AYCEO | EN | Operating instructions | 3.0 | Dokumentum
|
| POWERLINK 8400 E84AYCEC | DE | Operating instructions | 3.0 | Dokumentum
|
| POWERLINK 8400 E84AYCEC | EN | Operating instructions | 3.0 | Dokumentum
|
| PROFIBUS 8400 E84AYCPM | DE | Operating instructions | 2.2 | Dokumentum
|
| PROFIBUS 8400 E84AYCPM | EN | Operating instructions | 2.2 | Dokumentum
|
| PROFINET 8400 E84AYCER | DE | Operating instructions | 11.0 | Dokumentum
|
| PROFINET 8400 E84AYCER | EN | Operating instructions | 11.0 | Dokumentum
|
Error codes
| Cause | Remedy | Severity/response |
|---|---|---|
DC-bus voltage has exceeded the error threshold for overvoltage due to a too high braking energy or a too high mains voltage. The error threshold (display in 0x2540:006 (P208.06) results from the setting of the rated mains voltage in 0x2540:001 (P208.01). |
Reduce dynamic performance of the load profile. Check mains voltage. Check settings for brake energy 0x2541:001 (P706.01) = [0]: Connect brake resistor to the power unit and activate the integrated brake chopper |
Fault |
| Cause | Remedy | Severity/response |
|---|---|---|
Operation on uninterrupted 1x230V current supply (UPS) has been activated: Only a reduced output current is provided. |
Switch back to operation with regular mains voltage |
Warning |
| Cause | Remedy | Severity/response |
|---|---|---|
Mains phase failure |
|
Fault |
| Cause | Remedy | Severity/response |
|---|---|---|
DC bus voltage is lower than specified in C0173. |
|
cawc |
| Cause | Remedy | Severity/response |
|---|---|---|
Braking energy is too high. (DC−bus voltage is higher than set in C0173.) |
|
| Cause | Remedy | Severity/response |
|---|---|---|
|
Check drive dimensioning. |
| Cause | Remedy | Severity/response |
|---|---|---|
|
Check drive dimensioning. |
| Cause | Remedy | Severity/response |
|---|---|---|
|
Check drive dimensioning. |
| Cause | Remedy | Severity/response |
|---|---|---|
One of the motor phases has |
|
| Cause | Remedy | Severity/response |
|---|---|---|
Short circuit Excessive capacitive charging |
|
| Cause | Remedy | Severity/response |
|---|---|---|
Device utilisation (ixt) too high by frequent and too long acceleration processes. |
Check drive sizing.
|
Fault (configurable)
Blocking time: 2 s Setting parameters: 0x2D40:005 (P135.05) |
| Cause | Remedy | Severity/response |
|---|---|---|
Motor thermally overloaded, e. g. by an impermissible continuous current or by frequent or too long acceleration processes. |
Check drive sizing.
|
Fault (configurable)
Blocking time: 2 s Setting parameters: 0x2D4B:003 (P308.03) |
| Cause | Remedy | Severity/response |
|---|---|---|
Short circuit of motor cable |
Check motor cable for short circuit. |
Fault
Blocking time: 2 s |
| Cause | Remedy | Severity/response |
|---|---|---|
|
|
Fault
Blocking time: 2 s |
| Cause | Remedy | Severity/response |
|---|---|---|
|
|
Fault
Blocking time: 2 s |