0x23C3 Manufacturer Lenze Product category i550 Parameter POWERLINK switch position Data type U8 Default setting - (Read only) M - Fieldbus POWERLINK Factor 1
0x23C2:008 Manufacturer Lenze Product category i550 Parameter Active POWERLINK settings: Rx length Data type U8 Default setting - (Read only) M - Fieldbus POWERLINK Factor 1
0x23C2:007 Manufacturer Lenze Product category i550 Parameter Active POWERLINK settings: Tx length Data type U8 Default setting - (Read only) M - Fieldbus POWERLINK Factor 1
0x23C2:004 Manufacturer Lenze Product category i550 Parameter Active POWERLINK settings: Node ID Data type U8 Default setting - (Read only) M - Fieldbus POWERLINK Factor 1
0x23C1:004 Manufacturer Lenze Product category i550 Parameter POWERLINK settings: Node ID Data type U8 Default setting 0 M - A P Fieldbus POWERLINK Factor 1
0x23C0 Manufacturer Lenze Product category i550 Parameter POWERLINK communication Data type U8 Default setting No action/no error [0] M - Fieldbus POWERLINK Factor 1
0x23BE:003 Manufacturer Lenze Product category i550 Parameter Modbus TCP/IP diagnostics of last Rx/Tx data: Transmit offset Data type U8 Default setting 0 M - Fieldbus Modbus TCP/IP Display Code P585.03 Factor 1
0x23BE:001 Manufacturer Lenze Product category i550 Parameter Modbus TCP/IP diagnostics of last Rx/Tx data: Receive offset Data type U8 Default setting 0 M - Fieldbus Modbus TCP/IP Display Code P585.01 Factor 1
0x23B3 Manufacturer Lenze Product category i550 Parameter Switch position Data type U8 Default setting - (Read only) M - Fieldbus Modbus TCP/IP Display Code P509.00 Factor 1
0x23B1:006 Manufacturer Lenze Product category i550 Parameter Modbus -TCP/IP settings: Time-to-live value (TTL) Data type U8 Default setting 32 M - A P Fieldbus Modbus TCP/IP Display Code P510.06 Factor 1