0x4007:002 Manufacturer Lenze Product category i550 Parameter Monitorizarea sarcinii ridicate: timp de întârziere Data type U16 Default setting 3.0 s M - A P Fieldbus general Factor 10
0x4007:001 Manufacturer Lenze Product category i550 Parameter Monitorizarea sarcinii ridicate: prag de eroare Data type U16 Default setting 200.0 % M - A P Fieldbus general Factor 10
0x4006:003 Manufacturer Lenze Product category i550 Parameter Detectarea pierderii sarcinii: răspuns la eroare Data type U8 Default setting Fără răspuns [0] M - A P Fieldbus general Display Code P710.03 Factor 1
0x4006:002 Manufacturer Lenze Product category i550 Parameter Detectarea pierderii sarcinii: timp de întârziere Data type U16 Default setting 0.0 s M - A P Fieldbus general Display Code P710.02 Factor 10
0x4006:001 Manufacturer Lenze Product category i550 Parameter Detectarea pierderii sarcinii: prag Data type U16 Default setting 0.0 % M - A P Fieldbus general Display Code P710.01 Factor 10
0x4005 Manufacturer Lenze Product category i550 Parameter Prag de frecvență Data type U16 Default setting 0.0 Hz M - A P Fieldbus general Display Code P412.00 Factor 10
0x4004:003 Manufacturer Lenze Product category i550 Parameter Valori inițiale MOP: cuplu Data type U16 Default setting 0.0 % M - A P Fieldbus general Display Code P414.03 Factor 10
0x4004:002 Manufacturer Lenze Product category i550 Parameter Valori inițiale MOP: valoare PID Data type I16 Default setting 0.00 PID unit M - A P Fieldbus general Display Code P414.02 Factor 100
0x4004:001 Manufacturer Lenze Product category i550 Parameter Valori inițiale MOP: frecvență Data type U16 Default setting 0.0 Hz M - A P Fieldbus general Display Code P414.01 Factor 10
0x4003 Manufacturer Lenze Product category i550 Parameter Mod inițial MOP Data type U8 Default setting Ultima valoare [0] M - A P Fieldbus general Display Code P413.00 Factor 1