The i700 cabinet servo inverter is suitable for dynamic motion control and multi-axis applications. The interconnected system of single or double axis devices, in combination with the appropriate supplier and our controllers, is the right choice for automation applications.
Our controllers, such as the c520, can be used to conveniently solve almost all control tasks for coordinated movement of multiple axes with high dynamics. Thus, modern and modular machine controls can be implemented based on our software modules.
The i950 cabinet servo inverter can be used as a power extension of the i700 cabinet servo inverter in the range from 22 to 110 kW.
Highlights
- Integrated DC-bus connection
- Small overall width from 50 mm for the double axis
- Axis modules capable of multiple overloads for peak output currents between 5 and 64 A, double axes up to 32 A
- Autotuning function for quick and easy controller adjustment
- "Safe Torque Off (STO)" safety function
Documentation
| Title | File | Document type | Version |
|---|---|---|---|
| Flyer i700 cabinet servo inverter EN | Flyer | v1.1 en |
Error codes
| Cause | Remedy | Severity/response |
|---|---|---|
DC-bus voltage has exceeded the error threshold for overvoltage due to a too high braking energy or a too high mains voltage. The error threshold (display in 0x2540:006 (P208.06) results from the setting of the rated mains voltage in 0x2540:001 (P208.01). |
Reduce dynamic performance of the load profile. Check mains voltage. Check settings for brake energy 0x2541:001 (P706.01) = [0]: Connect brake resistor to the power unit and activate the integrated brake chopper |
Fault |
| Cause | Remedy | Severity/response |
|---|---|---|
Operation on uninterrupted 1x230V current supply (UPS) has been activated: Only a reduced output current is provided. |
Switch back to operation with regular mains voltage |
Warning |
| Cause | Remedy | Severity/response |
|---|---|---|
Mains phase failure |
|
Fault |
| Cause | Remedy | Severity/response |
|---|---|---|
DC bus voltage is lower than specified in C0173. |
|
cawc |
| Cause | Remedy | Severity/response |
|---|---|---|
Braking energy is too high. (DC−bus voltage is higher than set in C0173.) |
|