Skočiť na hlavný obsah

i950

The intelligent i950 cabinet servo inverter can be easily integrated into modular machine solutions on the basis of prepared technology applications - parameterization instead of programming.
The same architecture, the same engineering and the use of the same application software, based on decades of application experience, dissolve the boundaries between centralized and decentralized motion control. Our FAST Application Software Toolbox becomes universally usable. If required, the pre-designed software modules can be very easily customized and extended.
In addition, the i950 cabinet servo inverter serves as a power extension of the i750 cabinet servo inverter in the Lenze automation system in the range from 22 to 110 kW.
The requirements of the Ecodesign Directive, Standard EN IEC 61800-9-2, are met.

Highlights

  • Prepared technology applications, e.g. table positioning, electronic gearbox, winder
  • One Cable Technology (OCT)
  • Modular scalability for feedback system and fieldbus connections
  • Autotuning function for quick and easy controller adjustment
  • Integrated safety technology with a wide range of functions, complies with up to SIL 3/PL e Cat. 4
Obrázok
    Fault ID: 0016
    Hex: 0016
    Description: I2xt overload
    Keypad display: OC6
    Cause Remedy Severity/response
    • Frequent and too long acceleration processes with motor overcurrent.
    • Permanent motor overload with Imotor >Irmotor

    Check drive dimensioning.

    Fault ID: x018
    Hex: x018
    Description: I2xt overload advance warning
    Keypad display: OC8
    Cause Remedy Severity/response
    • Frequent and too long acceleration processes with motor overcurrent.
    • Permanent motor overload with Imotor >Irmotor

    Check drive dimensioning.

    Fault ID: 0015
    Hex: 0015
    Description: I x t overload
    Keypad display: OC5
    Cause Remedy Severity/response
    • Frequent and too long acceleration with overcurrent
    • Continuous overload with Imotor > 1.05 x Irx

    Check drive dimensioning.

    Fault ID: 0012
    Hex: 0012
    Description: Motor cable earth fault
    Keypad display: OC2
    Cause Remedy Severity/response

    One of the motor phases has
    earth contact.

    • Search for cause of short circuit.
    • Check motor cable.
    Fault ID: 0011
    Hex: 0011
    Description: Short circuit of motor cable
    Keypad display: OC1
    Cause Remedy Severity/response

    Short circuit

    Excessive capacitive charging
    current in the motor cable.

    • Search for cause of short circuit.
    • Check motor cable.

      Use motor cable which is shorter
      or of lower capacitance.