    Fault ID: 12816
    Hex: 0x3210
    Description: Fault - DC bus overvoltage
    Keypad display: DC Bus OV
    Cause Remedy Severity/response

    DC-bus voltage has exceeded the error threshold for overvoltage due to a too high braking energy or a too high mains voltage. The error threshold (display in 0x2540:006 (P208.06) results from the setting of the rated mains voltage in 0x2540:001 (P208.01).

    Reduce dynamic performance of the load profile.

    Check mains voltage.

    Check settings for brake energy
    management.

    0x2541:001 (P706.01) = [0]: Connect brake resistor to the power unit and activate the integrated brake chopper

    Fault

    Fault ID: 12672
    Hex: 0x3180
    Description: UPS operation active
    Keypad display: UPS oper. active
    Cause Remedy Severity/response

    Operation on uninterrupted 1x230V current supply (UPS) has been activated: Only a reduced output current is provided.

    Switch back to operation with regular mains voltage

    Warning

    Fault ID: 12576
    Hex: 0x3120
    Description: Mains phase fault 
    Keypad display: Mains Phase fail
    Cause Remedy Severity/response

    Mains phase failure

    • Check wiring of the mains connection.
    • Check fuses.

    Fault

    Fault ID: 1030
    Hex: 1030
    Description: Undervoltage in the DC bus
    Keypad display: LU
    Cause Remedy Severity/response

    DC bus voltage is lower than specified in C0173.

    • Check mains voltage
    • Check supply cable

    cawc

    Fault ID: 1020
    Hex: 1020
    Description: Overvoltage in DC bus
    Keypad display: OU
    Cause Remedy Severity/response

    Braking energy is too high. (DC−bus voltage is higher than set in C0173.)

    • Use braking unit or regenerative module.