i550 motec
The i550 motec frequency inverter for wall mounting and motor mounting in protection class IP66 (UL Type 4X indoor) is the optimal decentralized drive solution. The inverter can be extended for universal use with an extension box with disconnect switch with/without Type E combination motor controller and operating elements.
Fast mounting and easy commissioning thanks to user-friendly tools as well as connections for commercially available connectors are the focus of this inverter. Parameters, drive behavior and usability correspond to our proven frequency inverters. Rounded off by high energy efficiency, we thus offer a modern and sustainable drive solution.
The requirements of the Ecodesign Directive, Standard EN IEC 61800-9-2, are met.
Application areas: Conveyor drives, traveling drives, winding drives, hoist drives, extruders, packaging machines, pumps, fans, ...
Highlights
- Compact solution for decentralized drive technology, wall-mounted or motor-mounted, with high protection class IP66 (UL Type 4X indoor)
- Wall-mounted expandable: Extension box with disconnect switch with/without Type E combination motor controller and operating elements
- Fast mounting due to pluggable, standardized connections (plug & play)
- Four IO-Link ports with limited IO-Link master functionality for easy data exchange between IO-Link sensors and actuators
- Integrated regenerative module for very high energy efficiency - a brake resistor is no longer required
Documentation
Error codes
| Cause | Remedy | Severity/response |
|---|---|---|
Device utilisation (ixt) too high by frequent and too long acceleration processes. |
Check drive sizing.
|
Fault (configurable)
Blocking time: 2 s Setting parameters: 0x2D40:005 (P135.05) |
| Cause | Remedy | Severity/response |
|---|---|---|
Motor thermally overloaded, e. g. by an impermissible continuous current or by frequent or too long acceleration processes. |
Check drive sizing.
|
Fault (configurable)
Blocking time: 2 s Setting parameters: 0x2D4B:003 (P308.03) |
| Cause | Remedy | Severity/response |
|---|---|---|
Short circuit of motor cable |
Check motor cable for short circuit. |
Fault
Blocking time: 2 s |
| Cause | Remedy | Severity/response |
|---|---|---|
|
|
Fault
Blocking time: 2 s |
| Cause | Remedy | Severity/response |
|---|---|---|
|
|
Fault
Blocking time: 2 s |