Skip to main content

general

0x2D66:009

Manufacturer
Product category
Parameter
Mains failure control: Status mains failure control
Data type
Default setting
- (Read only)
M
A
Fieldbus
Display Code
P721.09
Factor

0x2D66:008

Manufacturer
Product category
Parameter
Mains failure control: Restart threshold
Data type
Default setting
0.0 Hz
M
A
Fieldbus
Display Code
P721.08
Factor

0x2D66:007

Manufacturer
Product category
Parameter
Mains failure control: Clear time
Data type
Default setting
20 ms
M
A
Fieldbus
Display Code
P721.07
Factor

0x2D66:006

Manufacturer
Product category
Parameter
Mains failure control: Setpoint ramp
Data type
Default setting
20 ms
M
A
Fieldbus
Display Code
P721.06
Factor

0x2D66:005

Manufacturer
Product category
Parameter
Mains failure control: DC voltage setpoint
Data type
Default setting
100 %
M
A
Fieldbus
Display Code
P721.05
Factor

0x2D66:004

Manufacturer
Product category
Parameter
Mains failure control: Reset time V-controller
Data type
Default setting
20 ms
M
A
Fieldbus
Display Code
P721.04
Factor

0x2D66:003

Manufacturer
Product category
Parameter
Mains failure control: Gain V-controller
Data type
Default setting
0.01000 Hz/V
M
A
Fieldbus
Display Code
P721.03
Factor

0x2D52:001

Manufacturer
Product category
Parameter
Monitoring settings: Hysteresis for speed setpoint reached
Data type
Default setting
0.0 %
M
A
Fieldbus
Factor

0x2D4B:005

Manufacturer
Product category
Parameter
Motor overload monitoring (i²xt): Thermal load
Data type
Default setting
- (Read only)
M
A
Fieldbus
Factor

0x2D4B:003

Manufacturer
Product category
Parameter
Motor overload monitoring (i²xt): Response
Data type
Default setting
Fault [3]
M
A
Fieldbus
Display Code
P308.03
Factor