0x2631:019 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:019 Parameter Function list: Activate preset (bit 1) Default setting Digital input 5 [15] M - A P Data type U8 Display Code P400.19 Factor 1
0x2631:021 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:021 Parameter Function list: Activate preset (bit 3) Default setting Not connected [0] M - A P Data type U8 Display Code P400.21 Factor 1
0x2631:024 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:024 Parameter Function list: MOP setpoint down Default setting Not connected [0] M - A P Data type U8 Display Code P400.24 Factor 1
0x2631:023 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:023 Parameter Function list: MOP setpoint up Default setting Not connected [0] M - A P Data type U8 Display Code P400.23 Factor 1
0x2631:022 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:022 Parameter Function list: Activate setpoint via HTL input Default setting Not connected [0] M - A P Data type U8 Display Code P400.22 Factor 1
0x2631:026 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus Sequencer Product category i550 Read more about 0x2631:026 Parameter Function list: Activate segment setpoint (bit 0) Default setting Not connected [0] M - A P Data type U8 Display Code P400.26 Factor 1
0x2631:025 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:025 Parameter Function list: Activate MOP setpoint Default setting Not connected [0] M - A P Data type U8 Display Code P400.25 Factor 1
0x2631:028 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus Sequencer Product category i550 Read more about 0x2631:028 Parameter Function list: Activate segment setpoint (bit 2) Default setting Not connected [0] M - A P Data type U8 Display Code P400.28 Factor 1
0x2631:027 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus Sequencer Product category i550 Read more about 0x2631:027 Parameter Function list: Activate segment setpoint (bit 1) Default setting Not connected [0] M - A P Data type U8 Display Code P400.27 Factor 1
0x2631:030 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus Sequencer Product category i550 Read more about 0x2631:030 Parameter Function list: Run/abort sequence Default setting Not connected [0] M - A P C Data type U8 Display Code P400.30 Factor 1