0x291F:033 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:21 Fieldbus general Product category i550 Read more about 0x291F:033 Parameter Skip frequencies: Output frequency Default setting x.xx Hz (Read only) M - A O Data type I32 Factor 100
0x291F:032 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:21 Fieldbus general Product category i550 Read more about 0x291F:032 Parameter Skip frequencies: Input frequency Default setting x.xx Hz (Read only) M - A O Data type I32 Factor 100
0x293A Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:21 Fieldbus general Product category i550 Read more about 0x293A Parameter Actual switching frequency Default setting - (Read only) M t A O Data type U8 Display Code P116.00 Factor 1
0x2948:001 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:23 Fieldbus general Product category i550 Read more about 0x2948:001 Parameter Torque setpoint: Actual torque setpoint Default setting x.x % (Read only) M - A O Data type I16 Factor 10
0x2949:003 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:23 Fieldbus general Product category i550 Read more about 0x2949:003 Parameter Torque limit source selection: Actual positive torque limit Default setting x.x % (Read only) M - A O Data type I16 Display Code P337.03 Factor 10
0x2949:004 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:23 Fieldbus general Product category i550 Read more about 0x2949:004 Parameter Torque limit source selection: Actual negative torque limit Default setting x.x % (Read only) M - A O Data type I16 Display Code P337.04 Factor 10
0x2B0F Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:23 Fieldbus MCTRL Product category i550 Read more about 0x2B0F Parameter Output frequency motor Default setting x.x Hz (Read only) M t A O Data type I16 Factor 10
0x2B0E Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:23 Fieldbus general Product category i550 Read more about 0x2B0E Parameter Frequency setpoint Default setting x.x Hz (Read only) M t A O Data type I16 Display Code P102.00 Factor 10
0x2B13:003 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:23 Fieldbus general Product category i550 Read more about 0x2B13:003 Parameter Additive voltage impression: Actual voltage Default setting x V (Read only) M - A O Data type I16 Factor 1
0x2BA1:008 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:23 Fieldbus MCTRL Product category i550 Read more about 0x2BA1:008 Parameter Flying restart circuit: Flying restart frequency Default setting x.x Hz (Read only) M t A O Data type I16 Display Code P718.08 Factor 10