0x2C11:003 Manufacturer Lenze Product category i550 Parameter High speed range: Tracking controller reset time Data type U16 Default setting 6.00 ms M - A P Fieldbus MCTRL Factor 100
0x2C11:002 Manufacturer Lenze Product category i550 Parameter High speed range: Tracking controller gain Data type U16 Default setting 200 % M - A P Fieldbus MCTRL Factor 1
0x2C11:001 Manufacturer Lenze Product category i550 Parameter High speed range: Lower limit Data type U16 Default setting 10 % M - A P Fieldbus MCTRL Factor 1
0x2C10:008 Manufacturer Lenze Product category i550 Parameter HF injection range Data type U16 Default setting 6.0 % M - A P Fieldbus MCTRL Factor 10
0x2C10:001 Manufacturer Lenze Product category i550 Parameter HF amplitude Data type U16 Default setting 50.0 V M - A P Fieldbus MCTRL Factor 10
0x2C03:006 Manufacturer Lenze Product category i550 Parameter Motor parameter (PSM): Q-axis inductance Lq Data type U32 Default setting 20.000 mH * M - A P Fieldbus MCTRL Display Code P352.06 Factor 1000
0x2C03:005 Manufacturer Lenze Product category i550 Parameter Motor parameter (PSM): D-axis inductance Ld Data type U32 Default setting 20.000 mH * M - A P Fieldbus MCTRL Display Code P352.05 Factor 1000
0x2C02:004 Manufacturer Lenze Product category i550 Parameter Motor parameter (ASM): Slip frequency Data type U16 Default setting x.x Hz (Read only) M - A O Fieldbus MCTRL Display Code P351.04 Factor 10
0x2BA1:008 Manufacturer Lenze Product category i550 Parameter Flying restart circuit: Flying restart frequency Data type I16 Default setting x.x Hz (Read only) M t A O Fieldbus MCTRL Display Code P718.08 Factor 10
0x2BA1:003 Manufacturer Lenze Product category i550 Parameter Flying restart circuit: Restart time Data type U16 Default setting 5911 ms * M - A P Fieldbus MCTRL Display Code P718.03 Factor 1